DRX-ACC
AC CURRENT INPUT SIGNAL CONDITIONER
Made in the USA
INFINITY
Electromagentic Compatibility
Year 2000 Compliant
What You need:
ò Your choice of the signal conditioner
ò IBM PC or compatible
ò Windows 3.1 or higher, or Windows 95
ò RJ12 connector with telephone cable
ò Adapter (DB9/25 to RJ12)
SETTING UP YOUR SYSTEM
DRN Computer Connection
INPUT RANGES
10 mA, 100 mA, 1 Amp, 5 Amp AC current Dedicated input terminals for (10, 100 mA same input), 1 Amp and 5 Amp. Return terminal common to all ranges.

DRX-ACCFREQUENCY RANGE
30 Hz to 1KHz

INPUT IMPEDANCE

  • 3.3 Ohms for 10, 100 mA input
  • 0.2 Ohms for 1 Amp input
  • 0.04 Ohms for 5 Amp input


  • ISOLATION

    Three way isolation up to 1800 V Peak for 1 minute, 354 V Peak continuous per IEC spacing. Common mode rejection 100 dB

    INPUT OVER-CURRENT PROTECTION

  • 10% Above full scale continuously
  • 100% Above full scale for 10 seconds


  • ANALOG TO DIGITAL TECHNIQUE

    Dual slope

    READ RATE

    3 readings/second

    ACCURACY AT 25 ░C

    ▒ 0.2% of FS from 30 Hz to 1 KHz

    TEMPERATURE STABILITY

  • 10, 100 mA Range 100 ppm/░C typical
  • 1 Amp Range 150 ppm/░C typical
  • 5 Amp Range 200 ppm/░C typical


  • STEP RESPONSE FOR RS485 OUTPUT

    2 seconds to 99% of the final value (Filter time constant = 64)

    RESPONSE TIME

    To verify the response time, check the carriage return <CR>, it will be sent at the end of the response. You can send another command after you receive the <CR>.
    i.e. send: *01X01 - response: 01X01<DATA><CR>
    Note:
    01 is address.

    Signal Conditioner
    WARM UP TO RATED ACCURACY
    30 minutes

    INPUT POWER

    10 to 32 Volt

    DC POWER CONSUMPTION

    2.4 Watts (100 mA at 24 V DC)

    OPERATING AMBIENT

    -5 to +55 ░C

    STORAGE TEMPERATURE

    -40 to +85 ░C

    RELATIVE HUMIDITY

    90% at 40 ░C non-condensing

    Help Price List Specifications Print Manual Manuals Home
     Home Home  Table of Contents TOC  Back Back  Next Next