DRX-ACC
AC CURRENT INPUT SIGNAL CONDITIONER
INPUT
RANGES
10 mA, 100 mA, 1 Amp, 5 Amp AC current Dedicated input terminals for (10, 100 mA same input), 1 Amp and 5 Amp. Return terminal common to all ranges. ![]() 30 Hz to 1KHz INPUT IMPEDANCE ISOLATION Three way isolation up to 1800 V Peak for 1 minute, 354 V Peak continuous per IEC spacing. Common mode rejection 100 dB INPUT OVER-CURRENT PROTECTION ANALOG TO DIGITAL TECHNIQUE Dual slope READ RATE 3 readings/second ACCURACY AT 25 ░C ▒ 0.2% of FS from 30 Hz to 1 KHz TEMPERATURE STABILITY STEP RESPONSE FOR RS485 OUTPUT 2 seconds to 99% of the final value (Filter time constant = 64) RESPONSE TIME To verify the response time, check the carriage return <CR>, it will be sent at the end of the response. You can send another command after you receive the i.e. send: *01X01 - response: 01X01<DATA><CR> Note: 01 is address.
30 minutes INPUT POWER 10 to 32 Volt DC POWER CONSUMPTION 2.4 Watts (100 mA at 24 V DC) OPERATING AMBIENT -5 to +55 ░C STORAGE TEMPERATURE -40 to +85 ░C RELATIVE HUMIDITY 90% at 40 ░C non-condensing |